Lantis Timer-Delay Timer V2 Manual
Timer / delay timer can be applied for a range of uses.
MODE 1 = Timer (Triggered)
When triggered the Unit works as a timer to switch a device on for the programmed time and then off and stay off until next trigger.
Mode 2 = Delay Timer (triggered)
When triggered the unit works as a delay timer to switch a device on after a programmed time and stay on until the next trigger
MODE 3 = Delay Timer (No Trigger)
On power on the unit will delay for the user progammed time and the switch on and stay on. No trigger needed.
MODE 4 = ON/OFF Timer (No Trigger)
On power on the unit will loop on and off for the user programmed time.(Flasher)
Supply Voltage: 9-12v
Switching Current: 500mA (Switching a Relay)
Trigger Voltage: 5-12v (opto isolated)
Max Time: 2 hours.
This unit can be user programmed for your particular application.